Fire alarm servicing and maintenance in the West Midlands

Fire alarm servicing that's booked in, done properly and kept on record, so your system works when it matters and you can prove it. We're SAFE Fire & Security Systems, a BAFE registered fire alarm service company based in Halesowen. Our own experienced engineers service and maintain commercial fire alarm systems across Birmingham, the Black Country and the wider West Midlands, whoever installed them.

  • Free site survey, no obligation
  • Six-monthly servicing to BS 5839-1
  • Breakdown cover on maintenance contracts
  • Open and closed protocol systems

Accredited & approved

NICEIC Approved ContractorBAFE Fire Safety Register, registered organisation ID 303478NSI approvedSafeContractor approvedConstructionline Gold memberBlack Country Chamber of Commerce member logo
★★★★★5.0 from 46 Google reviews

Is your fire alarm being looked after, or just left?

If you're the responsible person for a commercial building, the fire alarm is your duty, even if someone else fitted it and someone else is meant to be servicing it. These are the problems we find most often when we're asked to take a look:

  1. Faults showing on the panel that nobody has dealt with.
  2. Services that have slipped, with no clear record of what was tested or when.
  3. False alarms that keep emptying the building, again.
  4. A servicing company that has stopped returning your calls.

Leave it, and you risk a hard conversation with your insurer, a fire safety visit you're not ready for, or a system that doesn't do its job on the day it's needed. Good fire alarm maintenance takes all of that off your plate.

What a fire alarm service visit includes

BS 5839-1, the British Standard for fire detection and alarm systems in non-domestic buildings, recommends that a competent fire alarm company inspects and services your system at intervals of about six months. The 2025 edition allows some flexibility: a service any time between 5 and 7 months after the last one is acceptable, counted from the date the system was handed over.

At each service visit, our engineers:

  • Inspect the panel and the system, and deal with any faults showing.
  • Review the logbook for faults, false alarms and anything that's changed since the last visit.
  • Check the panel clock.
  • Confirm signals reach your alarm receiving centre, if your system is monitored.
  • Test detectors and call points on a rolling basis, so that over each 12 months every detector and call point has been tested.
  • Check the zone plan still matches the building.
  • Write up the visit in your logbook and issue your service certificate.

If we find something that needs putting right, we log it with photos and send you a clear quote, so nothing is done without your say-so. Our guide to BS 5839-1 for commercial buildings explains the standard in plain English.

SAFE engineer testing a manual fire alarm call point with a test key

Your part: the weekly fire alarm test

Servicing doesn't replace the weekly test. BS 5839-1 recommends that someone on site tests the system every week, using a different manual call point each time, checking the sounders work and writing the result in the logbook. If some staff only work out of hours, a monthly test at those times is a good idea too.

It only takes a couple of minutes, and we'll show you or your staff how to do it. Our guide how often should fire alarms be tested? sets out the full routine, from weekly checks to the yearly round of device tests.

Fire alarm maintenance contracts

A maintenance contract means your fire alarm is simply looked after, without you having to chase anyone.

  • Servicing booked in for you. Visits are scheduled in advance and repeat on your compliance cycle, so they never get missed.
  • Breakdown cover on maintenance contracts. If your fire alarm develops a fault between visits, you call us and we come out to put it right.
  • Repairs from engineers who already know your system. No starting from scratch every time something goes wrong.
  • Your records online. Every maintenance customer gets access to our customer portal, where you can see your service reports, certificates, defects and quotes, maintenance schedules and asset registers whenever you need them.

When an insurer, auditor or fire officer asks to see your fire alarm records, you'll have them in seconds.

SAFE engineer testing a smoke detector during a fire alarm service in a shop

We take over fire alarm systems from other companies

Unhappy with your current fire alarm service company, or not sure when your system was last serviced? We take over any system, whoever installed it.

We start with a free site survey, looking through your service history and your processes with you. We don't test or open up any equipment at the survey. Then we put the system on six-monthly servicing so you never have to chase it again. If you're tied into a contract elsewhere, we can survey now so everything's ready to switch the day your current agreement ends.

Open protocol and closed protocol systems

We work on both open protocol and closed protocol fire alarm systems. A closed protocol (or proprietary) system is tied to the manufacturer's own network of approved companies, so if you feel locked in, talk to us about your options. Our guide to open protocol vs closed protocol fire alarms explains the difference.

Cutting down false alarms

False alarms empty your building, interrupt your working day and wear down how seriously people take the alarm. Regular maintenance is one of the simplest ways to keep them down.

At every service we review the false alarms recorded in your logbook and look for the pattern behind them: a detector that doesn't suit the area it's in, a device that's dirty or failing, or a part of the building that's changed use since the system went in. Then we tell you plainly what we'd change. Sometimes that's as simple as swapping a detector type; sometimes the system has reached the end of its life, and our guide to the top 5 signs your fire alarm needs replacing will help you decide.

BAFE registered, NSI approved, our own engineers

Choosing between fire alarm maintenance companies comes down to one question: can you trust them to do it properly? Here's what you can check about us:

  • BAFE SP203-1 registered for the design, installation, commissioning and maintenance of fire detection and alarm systems.
  • NSI approved for our security systems work, and NICEIC approved for electrical work.
  • Our own experienced engineers, alongside apprentices we're training up in our in-house training suite.
  • Enhanced DBS-checked engineers, with work in schools planned around the school day.
  • 200+ projects completed and 550+ sites looked after, rated 5.0 from 46 Google reviews.

SAFE was set up by best mates Martin and Adam, engineers who learned the trade at large national companies and wanted to give local businesses a more personal service. Our guide how to choose a fire alarm company lists the questions worth asking any fire alarm service company before you sign.

Everything else in one visit

Most buildings that need fire alarm servicing need other fire safety checks too. We can look after them on the same contract, with one set of records in your portal:

  • Emergency lighting. Testing and maintenance of self-contained emergency lighting to BS 5266-1, with the monthly and annual tests done for you. See emergency lighting.
  • Fire extinguishers. Supply and servicing to BS 5306-3. When an extinguisher is due its 5-year discharge test or 10-year CO2 overhaul, we'll often recommend replacing it instead if that works out more cost effective. See fire extinguishers.
  • Fire alarm monitoring. We can connect your fire alarm to EMCS, our NSI Gold alarm receiving centre, so activations are passed on even when the building is empty. See alarm monitoring.
  • Fire risk assessments. We partner with select, highly experienced fire risk assessors we know and trust, and can put you in touch.

Need a new system rather than servicing? See our commercial fire alarm installation page.

Fire alarm servicing near you

From our base on Shelah Road in Halesowen, our engineers carry out fire alarm servicing and maintenance across the West Midlands, including:

We also cover Staffordshire and Shropshire. Not sure if you're in our area? Call 0333 224 0247 and ask.

SAFE Fire & Security office in Halesowen with a branded SAFE van outside

How it works

  1. Book your free site survey. Call 0333 224 0247 or fill in the form. We'll look through your system, your logbook and your service history, and talk you through it.
  2. Get a clear, written plan. What your system needs, how often we'll visit and what's included, before anything starts.
  3. Relax, it's looked after. We service on time, fix faults and keep your certificates in your customer portal.
FAQs

Fire alarm servicing: your questions answered

How often should a commercial fire alarm be serviced?
BS 5839-1 recommends a service by a competent company about every six months. The 2025 edition allows a service any time between 5 and 7 months after the last one. Six-monthly servicing is our standard, and every visit is logged.
What's included in a fire alarm service?
Each visit covers an inspection of the panel and system, a review of the logbook for faults and false alarms, a panel clock check, monitoring signals if you have them, and testing of devices, so that every detector and call point is tested over each 12 months. You get a service certificate and the visit is recorded in your logbook.
Can you take over a system another company installed?
Yes. We take over any system, whoever installed it, including open protocol and closed protocol systems. We start with a free site survey, looking through its service history with you. If you're mid-contract, we can get everything ready for the day it ends.
What happens if our fire alarm faults between services?
Customers on a maintenance contract have breakdown cover, so you call us and our engineers come out to put it right. Repairs are quoted first, so nothing is done without your say-so.
Do I still need to do the weekly test?
Yes. BS 5839-1 recommends a weekly test by someone on site, using a different call point each time and writing the result in the logbook. Servicing doesn't replace it, and we'll show your staff how to do it.
Can I see our fire alarm records online?
Yes. Every maintenance customer gets access to our customer portal, with service reports, certificates, defects, quotes and maintenance schedules in one place.
Are you BAFE registered?
Yes. We're registered under BAFE SP203-1 for the design, installation, commissioning and maintenance of fire detection and alarm systems. We're also NSI approved for security systems and NICEIC approved for electrical work.
Which areas do you cover?
Birmingham, the Black Country, Solihull, Coventry, Worcestershire, Warwickshire, Staffordshire and Shropshire, from our base in Halesowen.

Get your fire alarm servicing sorted by one trusted local team

Book a free site survey. We'll look at your system and your records, tell you straight what it needs, and get it on a proper servicing schedule.

SAFE Fire & Security Systems Ltd, La Husbands, Shelah Road, Halesowen, West Midlands, B63 3PP · Office open Monday to Friday, 8:30am to 5pm. Breakdown cover on maintenance contracts.

Call usFree site survey